Classifications

NEC Zone Classification (Class I, Zone 1) Lighting

Zone-Rated Lighting for Class I Hazardous Locations

Skip to results list

Filters

Filter

Active filters:

NEC Zone Classification (Class I, Zone 1) Lighting

NEC Zone classification is an alternative to the Class/Division system for rating hazardous locations in North America, using the Zone 1 and Zone 2 designations more commonly associated with international IEC standards.

Read More...

  • BLOCK H1 Series

    BLOCK H1 Series

    BLOCK H1 Series

    SKU BLK2 H1

    Explosion-proof, energy-efficient industrial lighting

  • BLOCK H2 Series

    BLOCK H2 Series

    BLOCK H2 Series

    SKU BLK2 H2

    Durable, versatile light for hazardous zones

  • BLOCK MINI H1 Series

    BLOCK MINI H1 Series

    BLOCK MINI H1 Series

    SKU BLM2 H1

    Compact, explosion-proof LED built for hazardous locations that demand reliability and long service life.

  • BLOCK MINI H2 Series

    BLOCK MINI H2 Series

    BLOCK MINI H2 Series

    SKU BLM H2

    Versatile C1D2 LED with multiple mounting options

  • LINEAR EMERGENCY Series

    LINEAR EMERGENCY Series

    LINEAR EMERGENCY Series

    SKU LNR EM

    Linear LED with emergency backup

  • LINEAR Series

    LINEAR Series

    LINEAR Series

    SKU LNR2

    Linear lighting in multiple lengths

  • LINEAR TUFF EMERGENCY Series

    LINEAR TUFF EMERGENCY Series

    LINEAR TUFF EMERGENCY Series

    SKU LNT EM

    Durable emergency light with 90-minute backup

  • LINEAR TUFF Series

    LINEAR TUFF Series

    LINEAR TUFF Series

    SKU LNT2

    Robust linear light for tough environments

  • MODULAR MAX Series

    MODULAR MAX Series

    MODULAR MAX Series

    SKU MDX

    Rugged LED delivering up to 70,000 lumens

  • ROUND MAX EMERGENCY Series

    ROUND MAX EMERGENCY Series

    ROUND MAX EMERGENCY Series

    SKU RDX EM

    Reliable haz-area emergency LED light

  • ROUND MAX Series

    ROUND MAX Series

    ROUND MAX Series

    SKU RDX

    Wide-coverage round light for large areas

  • ROUND RETROFIT Series

    ROUND RETROFIT Series

    ROUND RETROFIT Series

    SKU RTR RND2

    Hazardous location LED retrofit for existing HID fixtures.

  • ROUND Series

    ROUND Series

    ROUND Series

    SKU RND2

    Compact, powerful light for various applications

What NEC Zone Classification Means

The National Electrical Code (NEC) offers two parallel systems for classifying Class I hazardous locations: the traditional Class/Division system (Division 1 and Division 2), and the Zone system (Zone 0, 1, and 2), which was added to more closely align U.S. practice with the IEC Zone system used internationally. Class I Zone 1 and Class I Zone 2 apply the same underlying risk logic as Division 1 and Division 2 — how frequently a hazardous atmosphere is present — but use zone terminology and, in some cases, different equipment protection concepts.

A facility can choose either system, but generally shouldn't mix them within the same hazardous area — consistency in classification approach across a site's documentation and equipment simplifies both compliance review and future maintenance.

NEC Zones vs. NEC Divisions

Both systems classify the same underlying hazard, using different frameworks:

  • Class I Division 1 / Division 2 use the traditional NEC framework, historically the default choice for U.S. facilities.
  • Class I Zone 1 / Zone 2 use the newer NEC Zone framework, which more closely mirrors the IEC Zone system used internationally — often preferred by companies standardizing equipment and documentation across U.S. and international facilities.

Class I Zone 1 roughly corresponds to Class I Division 1, and Class I Zone 2 roughly corresponds to Class I Division 2, though the equipment protection concepts recognized under each system aren't always identical.

Where NEC Zone Classification Is Used

  • Multinational companies standardizing across U.S. and international facilities — using Zone terminology consistently across all sites
  • Facilities specified by engineers trained on IEC-style Zone classification — common with international engineering firms
  • Oil, gas, and chemical facilities with global operations — where Zone terminology may already be standard practice

Choosing Between Zones and Divisions

Confirm which system your facility's existing documentation, equipment, and engineering team already use — switching systems mid-facility adds complexity without a safety benefit. New facilities or those standardizing with international operations may prefer the Zone system; facilities with an established Division-based equipment base typically stay with Divisions.

Frequently Asked Questions

Is Class I Zone 1 the same as Class I Division 1?

They address the same underlying hazard frequency and are roughly equivalent, but they're technically distinct systems with some differences in recognized equipment protection concepts. Confirm which system your project specifies.

Can a facility use both Zones and Divisions?

The NEC generally expects consistency within a given hazardous area rather than mixing systems. A facility could use Divisions in one area and Zones in another, but not both within the same classified space.

Why would a U.S. facility choose Zone classification over Division?

Zone classification more closely aligns with the IEC system used internationally, which can simplify equipment sourcing and documentation for companies with both U.S. and international facilities.