Classifications

Class 1 Division 2 LED Lighting

Rated for Occasional Flammable Gas & Vapor Exposure

Skip to results list

Filters

Filter

Active filters:

Class 1 Division 2 LED Lighting

Class 1 Division 2 applies to locations where flammable gases or vapors are normally contained but could be present under abnormal conditions — such as equipment failure or a leak. Red Sky Lighting offers Class 1 Div 2 rated luminaires for these applications.

Read More...

  • BLOCK H2 Series

    BLOCK H2 Series

    BLOCK H2 Series

    SKU BLK2 H2

    Durable, versatile light for hazardous zones

  • BLOCK MINI H2 Series

    BLOCK MINI H2 Series

    BLOCK MINI H2 Series

    SKU BLM H2

    Versatile C1D2 LED with multiple mounting options

  • LINEAR EMERGENCY Series

    LINEAR EMERGENCY Series

    LINEAR EMERGENCY Series

    SKU LNR EM

    Linear LED with emergency backup

  • LINEAR Series

    LINEAR Series

    LINEAR Series

    SKU LNR2

    Linear lighting in multiple lengths

  • MODULAR MAX Series

    MODULAR MAX Series

    MODULAR MAX Series

    SKU MDX

    Rugged LED delivering up to 70,000 lumens

  • ROUND MAX EMERGENCY Series

    ROUND MAX EMERGENCY Series

    ROUND MAX EMERGENCY Series

    SKU RDX EM

    Reliable haz-area emergency LED light

  • ROUND MAX Series

    ROUND MAX Series

    ROUND MAX Series

    SKU RDX

    Wide-coverage round light for large areas

  • ROUND RETROFIT Series

    ROUND RETROFIT Series

    ROUND RETROFIT Series

    SKU RTR RND2

    Hazardous location LED retrofit for existing HID fixtures.

  • ROUND Series

    ROUND Series

    ROUND Series

    SKU RND2

    Compact, powerful light for various applications

What Class 1 Division 2 Means

Div 2 fixtures don't require the same containment level as Div 1, since the hazard is only expected under fault conditions rather than as a normal operating condition — but they still must prevent ignition if that hazard occurs. This typically means the fixture is designed to avoid producing an ignition source (arc, spark, or excess heat) during normal operation, since the hazardous atmosphere itself is not expected to be present under normal conditions.

Division 2 locations are common adjacent to Division 1 areas — for example, in a room next to a tank or process unit where gas is normally piped and contained, but a leak could introduce a hazardous atmosphere.

Division 2 vs. Division 1

The distinction comes down to how routinely the hazard is present:

  • Division 1 assumes the hazardous atmosphere is present regularly under normal operation.
  • Division 2 assumes the hazard is normally absent, contained, or ventilated, and only occurs under abnormal conditions.

Because the risk profile differs, Division 2 fixtures are often less complex (and less costly) than Division 1 fixtures rated for the same gas group, though they still require certification for the applicable classification.

Where Class 1 Division 2 Is Needed

  • Areas adjacent to Division 1 hazardous zones — buffer or transition spaces near a primary hazard source
  • Facilities where gas is normally piped or contained — risk exists only if containment fails
  • Petrochemical and industrial sites with occasional exposure risk — spaces requiring a lower but non-zero level of protection

Specifying the Right Fixture

Confirming whether a space is truly Division 1 or Division 2 requires a facility hazard assessment — the difference matters both for fixture cost and for correct code compliance. Facilities sometimes over-specify Division 1 fixtures throughout a site when Division 2 would be sufficient and code-compliant for certain zones, adding unnecessary cost.

Frequently Asked Questions

Can I use a Division 1 fixture in a Division 2 location?

Generally yes — Division 1-rated fixtures meet or exceed Division 2 requirements, since they're designed for a higher-frequency hazard. The reverse isn't true: a Division 2 fixture shouldn't be used in a Division 1 location.

How do I know if my facility is Division 1 or Division 2?

This is determined through a facility hazard assessment, typically performed by a qualified engineer or safety professional, based on how frequently a hazardous atmosphere is present under normal vs. abnormal conditions.

Is Class 1 Division 2 the same as Zone 2?

Class 1 Division 2 roughly corresponds to Zone 2 under the IEC/ATEX system, though the two systems aren't a precise one-to-one match. Confirm which classification system applies to your project.